Digital Oscilloscope

  • Digital Oscilloscope OSC oscillograph oscillometer
  • Digital Oscilloscope OSC oscillograph oscillometer
  • Digital Oscilloscope OSC oscillograph oscillometer
Digital Oscilloscope OSC oscillograph oscillometerDigital Oscilloscope OSC oscillograph oscillometerDigital Oscilloscope OSC oscillograph oscillometer

Digital Oscilloscope OSC oscillograph oscillometer

  • Model Number: UA5200
  • Measuring Range: 200Mhz
  • Record length: 40K
  • OEM/ODM: Welcome
  • Product description: Digital Oscilloscope OSC oscillograph oscillometer wholesale
  • INQUIRY


Key Specifications/Special Features:

Description:

1 GSa/s real-time sampling rate and 25GSa/s the equivalent sampling rate

• 200MHz Simulate Broadband

• Powerful trigger

• Large screen and humanized operation interface

• Integrated USB Host, support U disk storage, USB interface system upgrade

• 7"/64K color TFT true color LCD screen, waveform display and clear realistic

Ultra-thin design, light volume, easy to carry
Model UA5200
Simulate Broadband 200MHz
Real-time sampling 1GSa/s
Equivalent sampling 25GSa/s
Record length 40K
Time base scope
(s/div)
4nS/div-40S/div
Channel delay 500ps
Vertical system
AD converter 8 bit resolution, two channel acquisition at the same time
Vertical sensitivity 2mV/div-5V/div(In the BNC input)
Vertical displacement range ±50V(5V/div),±40V(2V/div~500mV/div),
±2V(200mV/div-50mV/div)±400mV(20mV/div-2mV/div)
Rise time(BNC ) ≤5ns
DC Gain Accuracy 2mV/div-5mV/div ±4% (sampling or average sampling)
10mV/div-5V/div±3% (sampling or average sampling)
Trigger system EXT (typical) from dc to 40 MHZ to 200 mv
Trigger sensitivity (edge-triggered type) EXT (typical) from dc to 40 MHz to 1V
AC:attenuation 10Hz below signal
high frequency suppression: > 80KHz will decay signal
Low frequency suppression: < 150KHz will decay signal
Noise suppression: reduce the triggering sensitivity
Trigger level range External (EXT) : + / - 1.2 V external failure (EXT / 5) : ±6V
Trigger level range accuracy
(typical)
rising and falling time≥20ns
Internal (ch1 and ch2) :±(0.3div×V/div)±4div from the center of screen
External(EXT): ±(6%set value+40mV)
External attenuation5(EXT/5): ±(6%set value+200mV)
Scope 100ns-10s
Trigger type
Edge-triggered rising and falling
Trigger pulse width Trigger mode: (greater than, less than, equal to, is not equal to) pulse width, (greater than, less than, equal to, is not equal to) the negative pulse width; Pulse width of the range:20nS-10S
Video trigger Signal system: support standard NTSC, PAL and SECAM broadcasting;
range:1-525 (NTSC) and 1-625 (PAL/SECAM)
Slope trigger Trigger mode: (greater than, less than, equal to, is not equal to) positive slope, (greater than, less than, equal to, is not equal to) the negative slope; Set time:20nS – 10S
Timeout triggers Starting along: rising, falling edge; Set  time:20ns-10s
Alternate trigger Internal trigger: edge, pulse width, video, slope
Triggering frequency counter Readout resolution: 6
Precision (typical) : ±30 PPM (including all reference frequency error and calculation error + 1)
Frequency range: exchange coupling, from the least 10 hz to nominal bandwidth.




FAQ

Q: Do you have stock?
A: Yes, normally we have stock; if no stock, lead time is 7~15 days.

Q: Can I have samples?
A: Samples are available for evaluation.

Q: Is OEM & ODM available?
A: OEM&ODM are welcome.


Please contact us freely, we will response with 2 hours at work time.
MP/Skype/WeChat/Whatsapp: +8618925271519
Office Tel: +86-755-27789939 23220858
E-mail: Cindy@tadacn.com

Scan the qr codeClose